Technical
Extracel™ Trial Kit (5.0 mL) Product Data Sheet
For research use only
PRODUCT DESCRIPTION
The Extracel™ Trial Kit is composed of Glycosil™ (CMHA-S, thiol-modified hyaluronic acid), Gelin-S™ (GTN-DTPH, thiol-modified gelatin), Extralink™ (PEGDA, polyethylene glycol diacrylate), and degassed, deionized water (DG Water™).
Solutions of Glycosil™ and Gelin-S™ form a transparent hydrogel when mixed with Extralink™. All lyophilized solids are blanketed by argon and under a slight vacuum.
STORAGE
Glycosil™and Gelin-S™
- Store Glycosil™ and Gelin-S™ in original vials at -20 °C for up to one year.
- Solutions can be stored at -20 °C for ~ one month if they are frozen immediately after reconstitution in their original argon blanketed vials.
- Do not mix Glycosil™ and Gelin-S™ prior to freezing.
- Freeze/thaw solutions a minimum number of times for best results.
- Solutions should be thawed at 37 °C on a rocker and used immediately after thawing.
- During thawing, solutions go through a gel-like phase before returning to their liquid state.
- Do not uncap the Glycosil™ and Gelin-S™ vials, since both materials disulfide crosslink in the presence of oxygen.
- Use a syringe to add DG Water™ and remove product from the vials.
Extralink™
- Store Extralink™ in the original vial at -20 °C for up to one year.
- Reconstituted solutions can be stored at -20°C for about a month.
INSTRUCTIONS FOR USE
Glycosil™, Gelin-S™, and Extralink™ solutions are prepared by dissolving the lyophilized solids in the DG Water™. When reconstituted, they will be in phosphate buffered saline (PBS) buffer pH ~7.4.
Extracel hydrogels (5.0 mL) should be prepared in the following manner:
- Remove Glycosil™, Gelin-S™, and Extralink™ vials from the -20 °C freezer and heat them to 37 °C (~30 minutes).
- Remove the DG Water™ from the -20 °C freezer and thaw in a 37 °C water bath (~15 minutes).
- Under aseptic conditions and using a syringe with the exact amount of liquid, add 2.0 mL of DG Water™ to the Glycosil™ vial. Repeat for the Gelin-S™ vial.
- Place both vials horizontally on a rocker at 37 °C (for maximum mixing). It will take <30 minutes for the solids to fully dissolve. Solutions will be clear and slightly viscous. Note: Vigorous shaking will speed up dissolving time.
- Under aseptic conditions and using a syringe with the exact amount of liquid, add 1.0 mL of DG Water™ to the Extralink™ vial. Invert several times to dissolve.
- As soon as possible, but within four hours of making the solutions, mix equal volumes of Glycosil™ and Gelin-S™. To mix, pipette back and forth or invert the vial.
- If encapsulating cells, add 400 µL of cells to 4.0 mL of Glycosil™ + Gelin-S™. Pipette back and forth to mix.
- To form the hydrogel, add Extralink™ to the Glycosil™ + Gelin-S™ mix in a 1:4 volume ratio (1.0 mL Extralink™ to 4.0 mL Glycosil™ + Gelin-S™). The total hydrogel volume with cells is 5.4 mL.
- elation will occur within ~20 minutes. Note: Each kit component has been tested and shows no evidence of bacteria growth.